刘文婷,贾伟萍,李陈巧,孙鹏,王鹏,安俊健.响应面优化酶解法测定烟用接装纸中淀粉含量[J].包装工程,2025,(5):166-172.
LIU Wenting,JIA Weiping,LI Chenqiao,SUN Peng,WANG Peng,AN Junjian.Optimization of Starch Content Determination in Tipping Paper for Cigarette with Enzymatic Hydrolysis by Response Surface Methodology[J].Packaging Engineering,2025,(5):166-172.
响应面优化酶解法测定烟用接装纸中淀粉含量
Optimization of Starch Content Determination in Tipping Paper for Cigarette with Enzymatic Hydrolysis by Response Surface Methodology
投稿时间:2024-07-22  
DOI:10.19554/j.cnki.1001-3563.2025.05.021
中文关键词: 烟用接装纸  淀粉含量  糖化酶  响应面法
英文关键词: tipping paper for cigarette  starch content  glucoamylase  response surface methodology
基金项目:
作者单位
刘文婷 湖北中烟工业有限责任公司武汉 430040 
贾伟萍 湖北中烟工业有限责任公司武汉 430040 
李陈巧 湖北中烟工业有限责任公司武汉 430040 
孙鹏 黄鹤楼科技园集团有限公司武汉 430040 
王鹏 湖北工业大学 绿色轻工材料湖北省重点实验室武汉 430068 
安俊健 湖北工业大学 绿色轻工材料湖北省重点实验室武汉 430068 
摘要点击次数:
全文下载次数:
中文摘要:
      目的 设计一种烟用接装纸中淀粉含量的测定方法。方法 选用糖化酶对烟用接装纸中的淀粉进行酶解,采用3,5-二硝基水杨酸(DNS)比色法对酶解产物葡萄糖含量进行测定,进而计算出烟用接装纸中的淀粉含量。研究在单因素试验分析的基础上,采用响应面分析法优化酶解法测定烟用接装纸中淀粉含量的最佳条件,建立数学模型,并对方法进行精密度和加标回收率的测试。结果 得到了酶解法测定烟用接装纸中淀粉含量的最佳条件,糖化酶用量为2.64 mg/mL,反应时间为35 min,反应温度为53 ℃,方法相关系数为0.999,淀粉检出限为1.1 mg/L,相对标准偏差为1.02%,加标回收率为95.2%~105%。结论 该方法操作简便,准确度高,适合于烟用接装纸中淀粉含量的测定。
英文摘要:
      The work aims to design a method for determining the starch content in tipping paper for cigarette. Glucoamylase was used to degrade the starch in the tipping paper for cigarette. The glucose of the enzyme hydrolysis product in the solution was measured by 3,5-dinitrosalicylic acid colorimetry (DNS colorimetry) and the starch content in tipping paper for cigarette was calculated. Based on the results of the single factor experiments, the response surface methodology was used to optimize the optimal conditions of starch content determination in tipping paper for cigarette with enzyme hydrolysis and establish the mathematical model. Meanwhile, the precision and recovery rate of the method were tested. The optimal determination conditions of starch in tipping paper for cigarette were glucoamylase dosage of 2.64 mg・mL–1, reaction time of 35 min, reaction temperature of 53 ℃, correlation coefficient of 0.999, detection limit of starch of 1.1 mg・L–1, relative standard deviation of 1.02% and recovery rate of 95.2%-105% respectively. The method is easy to operate, with high accuracy and it can be used to determine the starch content in tipping paper for cigarette.